  Datasheet File OCR Text:
  controller: C9536-01 monitoring, measurement and control of:  black light  ultraviolet rays (uv-a)  mercury-xenon lamp  high pressure mercury-xenon lamp  deuterium lamp  uv led uv power meter C9536-01, h9958 series sensor head: h9958 series  traceable to national standard in japan and a certificate of calibration is appended  flat spectral response characteristics over a wide uv region  ideal for monitoring / controlling light source power for photocatalyst  wide light-receiving angle close to cos information furnished by hamamatsu is believed to be reliable. however, no responsibility is assumed for possible inaccuracies or omissions. specifications are subject to change without notice. no patent rights are granted to any of the circuits described herein. ?007 hamamatsu photoni cs k.k. subject to local technical requirements and regulations, availability of products included in this promotional material may var y. please consult with our sales office. specifications over view features applications the C9536-01/h9958 series are optical power meters designed to measure absolute optical power of uv light (mw/cm 2 ). these optical power meters have a flat spectral response over a wide uv wavelength region, and are capable of measuring the opti- cal power independent of the spectral emission distribution of a light source to be measured. unlike commonly available uv power meters, optical power of various uv light sources can be easily measured with just one set of the C9536-01/h9958 ser- ies, without having to correct each wavelength of emitted light. parameter description / value measurement mode external interface power requirement dimensions (w h d) operating ambient temperature / humidity storage temperature / humidity weight this mode makes one measurement each time start switch is pressed. this mode makes continuous measurements at a sampling rate of 1 second. this mode displays a result integrated over a certain period of time (adjustable from 1 second to 5 minutes in 1 second steps). rs-232c internal battery or ac adapter 75 mm 110 mm 20 mm 0 c to +45 c / below 80 % -20 c to +50 c / below 80 % approx. 285 g one shot continuous integration parameter description / value type spectral response effective area measurement range dimensions (w h d) operating ambient temperature / humidity storage temperature / humidity weight 10 mm 1 w/cm 2 to 100 mw/cm 2 55 mm 75 mm 18 mm 0 c to +45 c / below 80 % -20 c to +50 c / below 80 % approx. 195 g h9958 310 nm to 380 nm h9958-01 300 nm to 410 nm left: controller C9536-01, right: sensor head h9958 series
tpt 1022e02 oct. 2007. ip figure 4: dimensional outline (unit: mm) uv power meter C9536-01, h9958 series hamamatsu photonics k.k., electron tube division 314-5, shimokanzo, iwata city, shizuoka pref., 438-0193, japan, telephone: (81)539/62-5248, fax: (81)539/62-2205 u.s.a.: hamamatsu corporation: 360 foothill road, p. o. box 6910, bridgewater. n.j. 08807-0910, u.s.a., telephone: (1)908-231-0960, fa x: (1)908-231-1218 e-mail: usa@hamamatsu.com germany: hamamatsu photonics deutschland gmbh: arzbergerstr. 10, d-82211 herrsching am ammersee, germany, telephone: (49)8152-375-0, f ax: (49)8152-2658 e-mail: info@hamamatsu.de france: hamamatsu photonics france s.a.r.l.: 19, rue du saule trapu, parc du moulin de massy, 91882 massy cedex, france, telephone: (3 3)1 69 53 71 00, fax: (33)1 69 53 71 10 e-mail: infos@hamamatsu.fr united kingdom: hamamatsu photonics uk limited: 2 howard court, 10 tewin road welwyn garden city hertfordshire al7 1bw, united kingdom, teleph one: 44-(0)1707-294888, fax: 44(0)1707-325777 e-mail: info@hamamatsu.co.uk north europe: hamamatsu photonics norden ab: smidesv?gen 12, se-171-41 solna, sweden, telephone: (46)8-509-031-00, fax: (46)8-509-031-01 e -mail: info@hamamatsu.se italy: hamamatsu photonics italia: s.r.l.: strada della moia, 1/e, 20020 arese, (milano), italy, telephone: (39)02-935 81 733, fax: (39)02-935 81 741 e-mail: info@hamamatsu.it web site www.hamamatsu.com figure 1: relative spectral response characteristics of detector (typ.) (h9958: 310 nm to 380 nm) figure 2: relative spectral response characteristics of detector (typ.) (h9958-01: 300 nm to 410 nm) tpt b0026ec figure 3: detector sensitivity vs. incident light angle (typ.) tpt b0028eb tpt b0038eb relative value (%) 0 20 40 60 80 100 angle (degree) -100 -80 -60 -40 -20 0 20 40 60 80 100 cos h9958/-01 tpt a0041ea tpt a0042ea  sensor head: h9958 series  controller: C9536-01 select enter hamamatsu uv power meter start stop power 75 110 20 analog output connector rs-232c connector dc inlet dc in analog out rs-232c lcd 47 15 18 55 26 55 75 2000 0.5 input window 14 effective area 10 4-m3 threded hole relative value (%) 0 20 40 60 80 100 200 250 300 350 wavelength (nm) 400 450 500 black light black light h9958 351 368 note: this uv power meter is not a spectrum measuring de- vice. depending on the emission wavelength or spectral range of light sources to be measured, it might be neces- sary to place a bandpass filter on the light source side for accurate measurement of optical power. relative value (%) 0 20 40 60 80 100 365 wavelength (nm) 200 250 300 350 400 450 500 mercury-xenon lamp uv led h9958-01


▲Up To Search▲   

 
Price & Availability of C9536-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X